Single Phase Mono block and Jet Pumps

LITTLE STAR L SON

NIAGARA – WATER LEVEL CONTROLLER

Suitable For

Single phase Monoblock / Open well / Jet Pumps

Features

• Switch off the water pump when the upper tank is full/when the sump is empty.
• Switch on the water pump when the upper tank is empty and when the sump has enough water.
• Switch off the water pump during the dry running mode.
• Magnetic tape Low-level high-level operation.
• Dry run protection(Sensor type).
• LED light indication.
• Power on delay timer.

Technical Specifications

Description Rating
Operating Voltage (AC) 1Ø – 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 120 X W 55 X H 190 mm
Operating Current For Load
Relay Load 1Ø – 20 Amp
Motor Rating**
Direct Load 1Ø – 2 HP
Indirect Load *** Any Size

LITTLE STAR NEW SON

NIAGARA – WATER LEVEL CONTROLLER

Suitable For

Single phase Monoblock / Open well / Jet Pumps

Features

• Top Tank Level Control.
• Bottom Tank Level Control.

Suitable For

Single phase Monoblock / Open well / Jet Pumps

Features

• Top Tank Level Control.
• Bottom Tank Level Control.

Suitable For

Single phase Monoblock / Open well / Jet Pumps

Features

• Top Tank Level Control.
• Bottom Tank Level Control.

Technical Specifications

Description Rating
Operating Voltage (AC) 1Ø – 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 120 X W 55 X H 190 mm
Operating Current For Load
Relay Load 1Ø – 20 Amp
Motor Rating**
Direct Load 1Ø – 2 HP
Indirect Load *** Any Size

LITTLE STAR MON

NIAGARA – WATER LEVEL CONTROLLER

Suitable For

Single phase Mono block / Open well /Jet Pumps

Features

• Top Tank Level Control.
• Bottom Tank Level Control.

Technical Specifications

Description Rating
Operating Voltage (AC) 1Ø – 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 120 X W 55 X H 190 mm
Operating Current For Load
Relay Load 1Ø – 20 Amp
Motor Rating**
Direct Load 1Ø – 2 HP
Indirect Load *** Any Size

SUPER STAR MON

NIAGARA – WATER LEVEL CONTROLLER

Suitable For

Single phase Mono block / Open well /Jet Pumps

Features

• Semi Automatic and Fully Automatic Operation.
• Top Tank Level Control.
• Bottom Tank Level Control.

Technical Specifications

Description Rating
Operating Voltage (AC) 1Ø – 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 120 X W 55 X H 190 mm
Operating Current For Load
Relay Load 1Ø – 20 Amp
Motor Rating**
Direct Load 1Ø – 2 HP
Indirect Load *** Any Size

1010 BSS

NIAGARA – WATER LEVEL CONTROLLER

Suitable For

Single phase Monoblock Openwell /Jet Pumps and Compressors

Features

• Top Tank Level Control.
• Bottom Tank Level Control.
• Low / High Voltage Cut-Off.
• Dry Run / Over Load Protection.
• Dry Run Restart Timer Facility.
• Delay On Timer.
• Cyclic Timer.
• Seven Segment LED Display Indication.
• Used Programmable Voltage & Current Settings.

Technical Specifications

Description Rating
Operating Voltage (AC) 1Ø – 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 120 X W 55 X H 190 mm
Operating Current For Load
Relay Load 1Ø – 20 Amp
Motor Rating**
Direct Load 1Ø – 2 HP
Indirect Load *** Any Size

1010 BSD

NIAGARA – WATER LEVEL CONTROLLER

Suitable For

Single phase Monoblock Openwell /Jet Pumps and Compressors

Features

• Top Tank Level Control.
• Bottom Tank Level Control.
• Low / High Voltage Cut-Off.
• Dry Run / Over Load Protection.
• Dry Run Restart Timer Facility.
• Delay On Timer.
• Cyclic Timer.
• Seven Segment LED Display Indication.
• Used Programmable Voltage & Current Settings.

Technical Specifications

Description Rating
Operating Voltage (AC) 1Ø – 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 120 X W 55 X H 190 mm
Operating Current For Load
Relay Load 1Ø – 20 Amp
Motor Rating**
Direct Load 1Ø – 2 HP
Indirect Load *** Any Size

1010 MOD

NIAGARA – WATER LEVEL CONTROLLER

Suitable For

Single phase Monoblock Openwell /Jet Pumps and Compressors

Features

• Top Tank Level Control.
• Bottom Tank Level Control.
• Low / High Voltage Cut-Off.
• Dry Run / Over Load Protection.
• Dry Run Restart Timer Facility.
• Delay On Timer.
• Cyclic Timer.
• Seven Segment LED Display Indication.
• Used Programmable Voltage & Current Settings.

Technical Specifications

Description Rating
Operating Voltage (AC) 1Ø – 150V to 270V
Operating Voltage for Float Sensor Min 12V DC
Dimension L 120 X W 55 X H 190 mm
Operating Current For Load
Relay Load 1Ø – 20 Amp
Motor Rating**
Direct Load 1Ø – 2 HP
Indirect Load *** Any Size