GSM Based 2G Automatic Pump Controller With GPRS Three Phase

GSM LITTLE STAR 2R BSN

NIAGARA – AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump Operation Status
    The available voltage at the site | Pump Load(Current)
    Motor ON/OFF status with real-time
    Power ON/OFF status as feedback to customers through SMS
     .
  • The pump can be operated from anywhere through mobile.
  • Low / High voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay On Timer,Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • Micro Controller Based Single Phase Preventer.

.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ – 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ – 10 Amp
Motor Rating**
Indirect Load *** Any Size

GSM LITTLE STAR 3R BSN

NIAGARA – AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump Operation Status
    The available voltage at the site | Pump Load(Current)
    Motor ON/OFF status with real-time
    Power ON/OFF status as feedback to customers through SMS
     .
  • The pump can be operated from anywhere through mobile.
  • Low / High voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In built Delay On Timer,Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • Micro Controller Based Single Phase Preventer.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ – 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ – 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM BSD

NIAGARA – AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ – 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 150 X H 100 mm
Operating Current For Load
Relay Load 3∅ – 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM BOD

NIAGARA – AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps.

Features

  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ – 300V to 470V
Calibration accuracy +/- 5%
Dimension L 150 X W 80 X H 350 mm
Operating Current For Load
Relay Load 3∅ – 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM WLC BOD

NIAGARA – AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps.

Features

  • GSM(T/R) based wireless level Transmitter / Receiver.
  • Top Tank Level Control.
  • Bottom Tank Level Control.
  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ – 300V to 470V
Operating Voltage for Float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 80 X H 350 mm
Operating Current For Load
Relay Load 3∅ – 10 Amp
Motor Rating**
Indirect Load *** Any Size

3010 GSM WLC BOD WITH WIFI

NIAGARA – AGRICULTURAL AUTOMATION

Suitable For

Three Phase Pumps.

Features

  • Top Tank Level Control.
  • Bottom Tank Level Control.
  • Regional Languages Select Option for Voice response.
  • Pump operation status
    The available voltage at the site | Pump Load (current)
    Motor ON/OFF Status with real-time
    Power ON/OFF status as feedback to customers through SMS
    .
  • The pump can be operated from anywhere through mobile.
  • Low / High Voltage Cut-Off.
  • Dry Run / Over Load Protection.
  • Dry Run Restart Timer Facility.
  • In-built Delay on Timer, Cyclic Timer, RTC Timer, Maximum Run Timer.
  • Adjustable Voltage & Current Settings.
  • User Programmable Timer Settings.
  • LCD Display Indication.

Technical Specifications

Description Rating
Operating Voltage (AC) 3∅ – 300V to 470V
Operating Voltage for Float Sensor Min 12V to Max 30V DC
Calibration accuracy +/- 5%
Dimension L 150 X W 80 X H 350 mm
Operating Current For Load
Relay Load 3∅ – 10 Amp
Motor Rating**
Indirect Load *** Any Size